Fig. 1: Schematic setting of gas-to-gas humidifier with fuel cell module
The humidifiers are designed for a plug-and-play operation. No further activation is necessary. The overview of the Ecomate products is summarized in the following table.

The Ecomate hollow fiber humidifiers for gas-to-gas humidification on air side are available in various geometry for power range 1-150 kW of fuel cell. The modules meet the typical operating conditions of fuel conditions having its optimum around 80 °C and pressure up to 3,0 bar (abs.). The principle of the working function is described on Fig. 1

Fig. 1: Schematic setting of gas-to-gas humidifier with fuel cell module
The humidifiers are designed for a plug-and-play operation. No further activation is necessary. The overview of the Ecomate products is summarized in the following table.
| Ecomate | H02G | H10N | H20N | H50N-FL | H100N |
|---|---|---|---|---|---|
| FC power range / kW | 1-3 | 3-10 | 10-45 | 45-90 | 90-150 |
| Dry flow rate / SLPM | 100 | 600 | 2.000 | 3.000 | 5.000 |
| Pressure drop dry side / kPa | 1,2 | 2,3 | 3,8 | 4,7 | 7,7 |
| Approach dew T / °C | 9 | 13,8 | 14,7 | 15,3 | 15,6 |
| Volume / L | 1,8 | 3,8 | 7 | 11 | 16 |
| Weight / kg | 0,8 | 1,5 | 3,2 | 4,8 | 6,2 |
Technical Datasheet - ecomate H02G - PDF, 402 Kb
Technical Datasheet - ecomate H10N - PDF, 316 Kb
Technical Datasheet - ecomate H20N - PDF, 279 Kb
Technical Datasheet - ecomate H50N-FL - PDF, 283 Kb
Technical Datasheet - ecomate H100N - PDF, 327 Kb